Product Overview:
Single gun full power160kW Double guns automatically distribute power according to BMS requirements Order No.: 200406041602Basic parameter
| 
					Product name | 
				160kW integrated double gun DC charger (automatic power distribution)  | 
			
| 
					AC input | 
				AC380V±15% | 
			
| 
					DC output voltage | 
				200-750VDC | 
			
| 
					Constant power voltage range | 
				300-750VDC | 
			
| 
					Overall output power | 
				160kW | 
			
| 
					Maximum output current of the whole machine | 
				500A | 
			
| 
					Single circuit maximum current | 
				250A | 
			
| 
					Number of outputs  | 
				
					2 gun | 
			
| 
					Power distribution mode | 
				The full power of single gun is 160kW, and the power of double guns is automatically distributed according to the requirements of BMS  | 
			
| 
					Degree of protection | 
				
					IP54 | 
			
| 
					Overall dimensions | 
				Overall size: 750*600*1770 | 
			
Performance parameter
| 
					Category | 
				
					Name | 
				
					Parameter | 
			
| 
					AC input | 
				
					Input system | 
				
					Three phase five wire(A+B+C+N+PE) | 
			
| 
					Input voltage range | 
				
					AC380V±15% | 
			|
| 
					Input frequency | 
				
					50±1Hz | 
			|
| 
					DC output | 
				
					Voltage stabilization accuracy | 
				
					≤±0.5% | 
			
| 
					Current stabilization accuracy | 
				
					≤±1% | 
			|
| 
					Output Voltage Ripple | 
				
					Peak coefficient ≤0.5%, effective value ≤0.5% | 
			|
| 
					Performance&function | 
				
					Power factor | 
				
					≥0.99 | 
			
| 
					Efficiency | 
				
					≥95% | 
			|
| 
					Standby power consumption | 
				
					≤0.03% of rated output power | 
			|
| 
					Current sharing unbalance | 
				
					≤±3% | 
			|
| 
					Protection | 
				
					Input overvoltage and undervoltage protection,  | 
			|
| 
					Environment condition | 
				
					Operating ambient temperature | 
				
					-20℃~+50℃, derating is required above 50℃ | 
			
| 
					Relative humidity | 
				
					5%~95% (no condensation) | 
			|
| 
					Altitude | 
				
					≤2000m, derating is required above 2000m |