Product Overview:
State Grid Six Unified Model Order No.: 200406000801Basic parameter
| Product name | 80kW single gun DC charger (State Grid customized machine) |
|
AC input |
AC380V±15% |
|
DC output voltage |
200-1000VDC |
|
Constant power voltage range |
300-1000VDC |
|
Overall output power |
80kW |
|
Maximum output current of the whole machine |
250A |
|
Single circuit maximum current |
250A |
| Number of outputs | 1 gun |
|
Power distribution mode |
Single gun full power80KW |
|
Degree of protection |
IP54 |
|
Overall dimensions |
Overall size: 700*400*1800 |
Performance parameter
|
Category |
Name |
Parameter |
|
AC input |
Input system |
Three phase five wire(A+B+C+N+PE) |
|
Input voltage range |
AC380V±15% | |
|
Input frequency |
50±1Hz | |
|
DC output |
Voltage stabilization accuracy |
≤±0.5% |
|
Current stabilization accuracy |
≤±1% | |
|
Output Voltage Ripple |
Peak coefficient ≤0.5%, effective value ≤0.5% | |
|
Performance&function |
Power factor |
≥0.99 |
|
Efficiency |
≥95% | |
|
Standby power consumption |
≤0.03% of rated output power | |
|
Current sharing unbalance |
≤±3% | |
|
Protection |
Input overvoltage and undervoltage protection, | |
|
Environment condition |
Operating ambient temperature |
-20℃~+50℃, derating is required above 50℃ |
|
Relative humidity |
5%~95% (no condensation) | |
|
Altitude |
≤2000m, derating is required above 2000m |