Two grid power

Power Equipment Of Two Grids

DFW-12 outdoor ring main unit

Product overview:

● Prefabricated charged touchable silicone rubber cable head is adopted, which is fully sealed, fully insulated, maintenance free, and can reliably ensure personal safety; ● Compact structure, compact and beautiful appearance, stainless steel double-layer box body, with a service life of more than 20 years; ● On the premise of not affecting the operation of the main network, it realizes regional power outage maintenance and reduces the scope of power outage; ● One or more SF6 load switches can be equipped with flexible and diverse wiring modes, and the branch outgoing line can reach 8 circuits at most; ● Lightning arrester, short circuit fault indicator, current limiting fuse, etc. can be selected to meet various user requirements.

Product model description

Outdoor ring main unit

Number of incoming circuits

Number of outgoing circuits

Number of branch circuits​

Branch circuit with switch​

Number of branch circuit switches: one switch can be omitted without writing​


Technical parameter

No. Name Parameter
1 Rated Voltage 12kV
2 Rated Current 630A
3 Power frequency withstand voltage (phase to ground) 42kV/min
4 Lightning impulse Voltage 75kV
5 Rated breaking current 630A
6

Rated short-circuit switching current (peak value)​

50kA
7 Rated short-time withstand current 25kA/4S
8

Rated peak withstand current​

50kA
9

Rated breaking capacitive current​

45A
10

Rated breaking inductive current​

16A
11

Full load breaking times​

100
12

Mechanical operation times of opening and closing​

2000


Typical wiring scheme

Model​

Wire number description​

Primary wiring diagram​

Outline dimension (L x W x H)​

DFW-102K

One in two branches with one switch​

  1180×1150×2300
DFW-103K

One in three branches with one switch​

1250×1150×2300
DFW-104K

One in four branches with one switch​

  1250×1150×2300
DFW-112K

One in one out two branches with one switch​

  1350×1150×2300
DFW-113K

One in one out three branches with one switch​

  1420×1150×2300
DFW-114K

One in one out four branches with one switch​

  1420×1150×2300
DFW-102K 2

One in two branches with two switches​

  1350×1150×2300
DFW-112K2

One in one out two branches with two switches​

  1500×1150×2300
DFW-103K3

One in three branches with three switches​

  1850×1150×2300
DFW-113K3

One in one out three branches with three switches​

​  2000×1150×2300


Outline Diagram



Infrastructure Diagram



Technical requirement
● The inner side of the brick wall shall be plastered with 1:3 cement mortar and treated with waterproof treatment;
● The through beam adopts Φ6 concrete operation;
● Foundation channel steel shall be subject to anti-corrosion treatment after fabrication;
● After the installation of the branch box, the surrounding of the base shall be sealed with cement;     
● Waterproof measures shall be taken at the entrance of the hole
● The grounding electrode shall be embedded in the foundation, and the grounding resistance shall meet the requirements of the power department

Ordering Instructions
● Product model and primary drawing can be provided if users have special requirements;
● Standard section of incoming and outgoing lines and branch cables;
● Number of lightning arresters and short circuit fault indicators selected;
● Material and color of shell.

Contact Information
Zhejiang Changzheng Electric Co., Ltd.
Address:No.159, Wei 16 Road, Yueqing EconomicDevelopment Zone, Yueqing City, Zhejiang Province
Service hotline:400-826-9123
website:www.changzheng.com.cn