Two grid power

Power Equipment Of Two Grids

S11-M fully sealed oil immersed power transformer

Product overview:

S11-M fully sealed oil immersed power transformer is applicable to the power system with AC 50Hz and rated working voltage of 10kV and below, and it is used as the distribution transformer in petroleum, metallurgy, chemical, textile, light industry and other enterprises and places with large dust. The product meets the standard GB1094.1-5.

Product model description

Three-phase

Design No.

Fully sealed

Rated capacity (kVA)

High voltage side voltage level (kV)


Structure characteristics

● Iron core
The iron core shall be cold rolled silicon steel sheet with high magnetic conductivity grain orientation. The iron core is a core type iron core, which is a fully inclined seam stacked iron core. The iron core column is a circular section with multi steps, and the iron yoke and iron core are of equal section.
● Winding
The winding is made of corrugated oil duct, which is not dipped in paint, and is bound with tight tape. The windings are all concentric coils. The high-voltage winding has a tap corresponding to the tapping voltage requirements, which is led to the tapping switch, which is installed on the box cover. The tapping voltage can be changed only after the power supply is cut off.
● Safety protection device 
30~2000kVA transformers are equipped with pressure relief valves;
Gas relay with alarm and trip terminal can be installed according to user requirements;
● Oil temperature measuring device
All transformers are equipped with tube sockets of glass thermometer, which are set at the top of the oil tank and extend into the oil for 120±10mm;
1000~2000kVA transformers are equipped with outdoor signal thermometers;
● Transformer oil tank
The transformer oil tank is composed of corrugated walls, the surface is sprayed with powder and the paint film is firm. The corrugated heat sink not only has the cooling function, but also has the "breathing" function. The elasticity of the corrugated heat sink can compensate for the change of transformer oil volume caused by temperature rise and fall. Therefore, the fully sealed transformer has no oil conservator, which reduces the overall height of the transformer; The vacuum oil injection process is adopted when the transformer is packaged, which completely removes the moisture in the transformer, and the transformer oil does not contact with the air. It effectively prevents the possibility of transformer insulation performance degradation and transformer oil aging caused by oxygen and moisture intrusion into the transformer, so it is unnecessary to conduct oil sample test regularly.​


Conditions of use​

Altitude: no more than 1000m;

Ambient temperature: - 40~+40;

Note: When ordering this product beyond the above conditions, please consult with our company.


Technical parameter


Note: The load loss value above the diagonal line in the table is applicable to Dyn11 or Yzn11 connection group, and the load loss value below the diagonal line is applicable to Yyn0 connection.​


Outline and installation dimensions

Installation dimension (mm)​



Ordering Instructions

When ordering, the product model, rated capacity, high and low voltage rated voltage, high-voltage tapping range, number of phases, frequency and connection group symbol shall be provided.​

Contact Information
Zhejiang Changzheng Electric Co., Ltd.
Address:No.159, Wei 16 Road, Yueqing EconomicDevelopment Zone, Yueqing City, Zhejiang Province
Service hotline:400-826-9123
website:www.changzheng.com.cn